The appellant, [X. AG] (construction machinery and transport systems), manufactures, among other things, intermediate bulk containers (IBC), which are considered dangerous goods packagings (GGU) within the meaning of the Dangerous Goods Packaging Ordinance (CHMO). It held a quality assurance programme (QSP) under EN ISO 16106:2006 pursuant to No. 6.5.4.1 RID/ADR, which was audited in January 2011 by the then Swiss Dangerous Goods Inspectorate (EGI) and recognised until 12 January 2014.
[Y. AG] , a conformity assessment body (KBS) of type Xa, took over the type approval, the monitoring of manufacture and the initial inspection of the IBC. [Z. AG] was the only KBS designated for the recognition and monitoring of QSPs. After the recognition expired, [Z.] requested a date for a monitoring inspection. The Federal Office of Transport (BAV) stated in letters of 30 July and 12 August 2014 that the IBC manufactured since 12 January 2014 may not be placed on the market.
By decision of 27 October 2014, the BAV found that the IBC manufactured after 12 January 2014 did not comply with the provision concerning the QSP, prohibited their placing on the market, set a deadline for an exception application and threatened a recall in case of non-compliance. On the same day, [Z.] carried out a repeat audit and, subject to corrective measures, recognised a satisfactory QSP.
The appellant challenged the decision and the applications before the Federal Administrative Court (proceedings A-4979/2014 and A-6829/2014). The Federal Administrative Court joined the proceedings and dismissed the appeal by judgment of 18 February 2015, insofar as it had not become moot. The appellant lodged a public law appeal with the Federal Supreme Court and requested a declaration that the dismissal violated federal law or was based on a manifestly incorrect establishment of the facts. The BAV requested dismissal; the Federal Administrative Court and the DETEC waived their responses.
Considerations
The Federal Supreme Court affirmed the admissibility of the appeal (Art. 82 let. a, Art. 86 para. 1 let. a, Art. 90 FSCA). No ground of inadmissibility existed, in particular neither a type approval nor an examination or capability assessment within the meaning of Art. 83 FSCA. A current practical legal interest existed, because the lawfulness of the IBC manufactured between January and autumn 2014 depended on the decision and the monitoring contract with [Z.] was linked to the lawfulness of the decision. Requests 2 and 3 of the appeal of 5 September 2014 had become moot; decision paragraphs 2-5 of 27 October 2014 were deemed to be also contested despite a misleading layperson's wording.
The Federal Supreme Court examined the complaints regarding the facts under Art. 105 and 97 FSCA. Most complaints concerned questions of law. However, it was correct that [Y. AG] had not stated in its letter of 8 July 2014 that the legal situation had changed through the CHMO; rather, after the new directive entered into force, the BAV had required additional monitoring of the QSP by a designated KBS.
Under Art. 5 CHMO, GGU may be placed on the market if they comply with the provisions of RID/ADR. According to No. 6.5.4.1 RID/ADR, IBC must be manufactured and tested under a quality assurance programme recognised by the competent authority. The more detailed requirements, in particular the competent authorities and procedures, are to be laid down in domestic law. According to Annex 1 CHMO, the provisions of Chapter 6.5 RID/ADR are deemed met if the procedures are carried out by the KBS provided for in Table 1. Table 1 provides for type approval, monitoring of manufacture, initial inspection and recurring inspections. The KBS are designated by DETEC under Art. 15 CHMO and Annex 5 CHMO.
The lower court assumed that [Y. AG] was not designated for the recognition and monitoring of QSPs, which is why a repeat audit by [Z.] was necessary. The Federal Supreme Court held that the recognition of the QSP does not fall outside Annex 1 CHMO but belongs to the monitoring of manufacture. The Xa-KBS named in Annex 1 CHMO are therefore in principle also competent for the monitoring of quality assurance programmes. A decision by [Y. AG] on its limited scope of designation could not be challenged by the appellant, because only the KBS concerned has standing.
However, the Federal Supreme Court held that not every Xa-KBS must be recognised for all four procedures. The supervisory authority has technical discretion, and directives are not binding on the courts but must be taken into account insofar as they specify the statutory provisions without altering them. The reference to the German BAM-GGR 001 is permissible because the administration has technical discretion. The criticism of a duplication of inspection is unfounded, as the initial inspection may also be carried out by an in-house inspection service. The BAV's order that the QSP be inspected and recognised by a KBS designated for that purpose was therefore lawful.
As regards retroactivity, the Federal…